DataMan                                                                             By: Robert E. Sult  AOS
 
DATA MAN S4
 

 
 RED LABEL S4 (PROGRAMMER)  GREEN LABEL S4 (40 Pin Socket)
 GOLD LABEL S4 (Validator 1 Line SIG)
 SILVER &  ORANGE LABEL S4 (SHA SIG)

 
Data Man S4
VALIDATOR
 1) Insert the Gold S4 Library rom into the ZIP socket
E-Prom notch facing upwards
E-Prom placed at bottom of socket – towards the lever
                Turn on the DATAMAN
2) Press the RED (LIB) button
3) Press the RED (ENTER) button
SHOULD READ (SHOW) 
 
  
REMOVE GOLD S4
4) Insert the E-Prom you want to get the signature from
5) Press the GREEN (SUM) button
Should show you the CHIP NUMBER                              Example 29F010
Hear some beeps
Then will show you the signature                                  Example: Sig:  3C5C9PAA
 

BURNING E-PROMS
 
1) Insert the RED S4 Library rom into the ZIP socket
2) E-Prom notch facing upwards
3) E-Prom placed at bottom of socket – towards the lever TURN ON THE DATAMAN
4) Press the RED (LIB) button
5) Press the RED (ENTER) button
6) Should Show 
               REMOVE RED S4 LIBRARY
7) Insert the E-Prom that you want to copy
8) Press the GREEN (PROM) button to select E-Prom Type
9) Use up/down keys for Mfg.
10) Use left/right keys for size
11) Press the RED (ENTER) button
12) Press the GREEN (LOAD) button then RED (ENTER) button
 
  Press the Green Sum for Ck Sum
FOR FLASH CHIPS
 Insert flash chip
Press GRAY (FUNC) button then press GREEN (BURN) button then RED (ENTER) button – this will erase the Flash Chip
 Press The GREEN (BURN) button then the RED (ENTER) button – this will burn the Flash Chip.
When done it will show – Example 

                                 
 FOR E-PROMS
Insert E-Prom
Press GREEN (TEST) button then press then RED (ENTER) button
This will test E-Prom to insure it is blank and ready to burn.
Should Show: Will Burn
 
Press the Green (BURN) button then the RED (Enter) button
This will burn the E-Prom
When done it will show- Example                               
  

 
40 PIN SOCKET
Insert the GREEN S4 Library rom into zip socket
E-Prom notch facing upwards
E-Prom placed at bottom of socket – towards the lever
 
TURN ON THE DATAMAN
Press the RED (LIB) button
Press the RED (ENTER) button
 Should Read
REMOVE GREEN S4 LIBRARY
Insert the 40-pin socket
By: Robert E Sult
 

 
 
We had a problem with the Dataman would not turn on.
We would have to Turn it on then press the Reset Button, but this would only stay on for about a minute. Then Black out
 
 
S4's which have been left unused, and uncharged for a long period of time v\ have flat batteries .The charging circuit works under microprocessor control, therefore your unit needs to power up for the charger to actually charge the batteries. Getting such an S4 to power up can be difficult, but is usually possible.
 
It is no use leaving the charger plugged in. Doing this will not charge the battery.
• The only way to start 54 is to manually override the microprocessor controlled charging system.
• If your S4's serial number is less than 12000 or greater than 18800, then the following procedure to start your S4:
 
Plug in the S4 charger, and leave the S4 switched off. Press and hold in the reset button (this is an indented button just above the on/off switch on your (S4) for at least 30 seconds. Release the reset button, and switch on. S4 should now power up.
 
Press ENTER if asked START LIBRARY?
Press INFO, and the display will inform you of battery voltage, temperature, and whether or not the charger is connected and switched on/off.
 
If necessary force your unit to charge the battery by pressing the right-hand cursor keep until the display reads that the charger is switched ON.
 
Once this has been established then turn the S4 off by the switch (not by the power supply). Display will now inform you that S4 will switch off when charging is complete then when the display goes blank, your unit is fully charged.
 
If your S4s serial number is between 12000 and 18800, then you may need to hold in the reset button, and then plug in the charger.
Then continue t hold the reset button for 30 seconds. If this fails please contact Dataman advice.
Call us on +44 0 1300 320719 and ask for technical support.
 
NOTE! The S4 unit itself does not regulate the charging current it draws; it relies on the charger to do this.
The rating for the S4 charger is as follows:
Input: 240 VAC- 60 Hz Output: 12 VAC~ 650mA
.