Big Bertha
DBV (CODE 97)
Code 97 is Bill Validator abnormal status. This code comes up Bill Validator and or 8800 Bill & RS422 PCB broken. If you have in stock Bill Validator and or 8800 Bill & RS422 PCB, you should try to change these first. After change BV and or PCB but srill comes code 97, temporary solutions are turn off BV setting DIP-SW on 8800-A2MK main PCB. After change DIP-SW setting, you have to do main PCB's RAM clear. Please see following DiP-SW Setting and RAM Clear procedures, 2. DIP SW2 (8800-A2MK) 1-4
1
 
2
 
3
 
4
 
DESCRIPTION
 
OFF
 
OFF
 
OFF
 
 
 
Bill changer inactivated
 
ON
 
OFF
 
OFF
 
 
 
Value of Denomination 5c (1/20)
 
OFF
 
ON
 
OFF
 
 
 
10c(l/10)
 
ON
 
ON
 
OFF
 
 
 
25c (1/4)
 
OFF
 
OFF
 
ON
 
 
 
50c (1/2)
 
ON
 
OFF
 
ON
 
 
 
$1.00 (1/1)
 
OFF
 
ON
 
ON
 
 
 
$5.00 (5/1)
 
ON
 
ON
 
ON
 
 
 
$10.00(10/1)
 
 
 
 
 
 
 
OFF
 
"MARS GL5" or "CBV IVO" Bill Validator
 
 
 
 
 
 
 
ON
 
"JCM DBV-145-SS" Bill Validator
 
 
Remarks
If you change setup DIP switch 2 #1 through #4 you must clear Ram
 otherwise software can not change status.
setting for no Bill Validator, DIP-SW 2 (4 pole) 1 to 3 ALL OFF.
All Clear Procedure
Turn off power Press holds ALL CLEAR, switch (white small switch) located on 8800-A2MK PCB near the main CPU. Turn On power, press hold at least 5 second all clear switch.